DLMS/COSEM · Meter data · Energy billing

Every meter's data,
in your own database.

MaxDLMS reads your DLMS/COSEM electricity meters over TCP/IP, RS-485 or optical probe and stores every load profile in your own MySQL database, with no gaps. Monthly energy reports, tariffs and invoices, alerts and an API come from the same Windows service.

  • Live with 109 meters at the University of Jordan
  • Back-fills automatically after any outage, so no reading is lost
  • On your own PC and network: no cloud, no internet needed
MaxDLMS · Dashboard (demo data)
MaxDLMS dashboard with meter status, last sweep and energy overview
109 meterslive at the University of Jordan
TCP · RS-485and optical probe
MySQL · SQL Serveryour data, your database
Reports · Invoicestariffs and monthly energy
Why MaxDLMS

Smart meters record everything. Getting it out is the hard part.

Every DLMS meter on a campus, a factory or a building portfolio keeps a detailed load profile, but the vendor's reading tool is usually a manual, one-meter-at-a-time job, and the data ends up in spreadsheets or a closed system.

MaxDLMS reads all your meters on a schedule, stores every interval in a database you own, and turns it into energy reports and invoices your finance team can use.

Without MaxDLMS

  • Meters read by hand with the vendor's tool
  • Gaps whenever a meter or the network was down
  • Bills built from spreadsheets

With MaxDLMS

  • All meters read automatically, around the clock
  • Missing intervals back-filled from the meter's own memory
  • Energy reports and invoices straight from measured data
Features

From the meter to the invoice

One Windows service collects, stores, checks and reports. The web UI runs from the same program.

DLMS/COSEM load profiles

Load profiles and registers read from every meter on a schedule, with scaler and unit discovery and per-meter capture periods.

TCP, RS-485 & optical

TCP/IP (WRAPPER) meters, RS-485 buses (HDLC) from a COM port or a serial-to-Ethernet converter, and optical-probe reads (IEC 62056-21).

Gap-free backfill

What to read is worked out from what is stored, so after an outage each meter is caught up from where it stopped, saved meter by meter.

Meter model catalogue

Holley (field-proven), ION, Landis+Gyr and generic DLMS models. New makes are added in the web UI. Security: None, Low (password) or HLS.

Your database, mirrored

MySQL is the record. Exact copies go to SQL Server, SQLite or another MySQL server, and a SQL Server push feeds other systems.

Energy charts & readings

Daily and monthly energy per meter or for the whole site, plus a readings browser with CSV and Excel export.

Alerts

E-mail and webhook alerts when meters stop answering, the network drops or a database copy falls behind.

REST API

Meters, status, readings, energy and billing over /api/v1, with API keys and scopes, JSON or CSV.

Audited corrections

Manual corrections and imports are versioned: who changed what and when, with the meter's own value kept so it can be restored.

The web UI

See every meter at a glance

Served by MaxDLMS itself, on your network. Screenshots from a demo system with 109 simulated meters.

Runs as a Windows service
Works without internet access
Admin and viewer accounts
Light and dark theme
How it works

From meter to report, automatically

One program on one Windows PC on your meter network.

TCP/IP metersDLMS WRAPPER RS-485 busesCOM port or converter Optical probeIEC 62056-21 MaxDLMSread · backfill · check MySQL+ SQL Server / SQLite copies Web UIcharts, reports, invoices API · alertsREST, e-mail, webhook
1

Read

On a schedule, every meter's load profile is read from where the database left off.

2

Store

Each meter is saved as soon as it finishes, in UTC, and copied to any mirrors.

3

Check

Silent meters, port failures and lagging mirrors raise alerts by e-mail or webhook.

4

Report

Energy charts, monthly reports, invoices and the API, from measured data only.

MaxDLMS · Monthly energy report (demo data)
Monthly energy report with energy per meter
Reports & billing

Bills from measured energy, not estimates

For campuses, landlords, industrial parks and utilities that recharge energy to tenants, departments or customers:

  • Tariffs per meter: time-of-use periods and consumption blocks, set up in the web UI or imported.
  • Honest invoices: priced only from measured intervals. A gap marks the invoice incomplete, never filled with a guess.
  • Proper numbering: invoices numbered without gaps, frozen when issued, and corrected with credit notes.
  • Automatic exports: the monthly energy report and invoice drafts written to Excel on a schedule.
Ask about billing →
Client reference

Proven on a university campus

University of Jordan · MaxDLMS

Campus energy metering

Amman, Jordan · 109 DLMS meters

Every campus meter read automatically over TCP/IP into the university's own MySQL database, with full load-profile history, energy reports and a web UI for the facilities team.

Technical details

MaxDLMS at a glance

Protocol
DLMS/COSEM: load profiles (generic profiles), registers, clock, scaler and unit.
Connections
TCP/IP (WRAPPER, one endpoint per meter); RS-485 HDLC on a COM port or a serial-to-Ethernet converter; optical probe IEC 62056-21 mode E.
Security
None, Low (password) and HLS. Meter secrets encrypted on the PC and never shown in the UI.
Meter models
Holley (field-proven), ION, Landis+Gyr and generic DLMS; custom models defined in the web UI.
Storage
MySQL primary in UTC; mirrors in SQL Server, SQLite or MySQL; SQL Server push for third-party systems; optional retention.
Web UI
Dashboard, meters, buses, models, readings browser, energy, monthly report, tariffs and invoices, users, API keys, settings.
Exports
CSV and Excel (.xlsx); readings import from CSV or Excel; scheduled report exports.
API
REST /api/v1 with API keys and scopes; JSON or CSV; documented in the web UI.
Alerts
E-mail (SMTP) and webhook.
Deployment
Windows service, single program, no internet needed; licensed per PC by number of meters.
FAQ

Frequently asked questions

Straight answers about MaxDLMS. Anything else? Ask us below.

Which meters can MaxDLMS read?

DLMS/COSEM electricity meters. Holley meters are field-proven at the University of Jordan; ready models also exist for ION, Landis+Gyr and generic DLMS meters, and any other DLMS meter is added as a model in the web UI: addressing, security, capture period and channels, with no new software.

How are the meters connected?

Over TCP/IP (DLMS WRAPPER, one IP address per meter), over RS-485 serial buses (HDLC) from a COM port or a serial-to-Ethernet converter, or with an optical probe (IEC 62056-21) for manual reads.

What happens when a meter or the network is down?

Nothing is lost. MaxDLMS works out what to read from what is already stored, so after an outage it back-fills each meter's load profile from where it stopped, oldest first and in small slices, and saves each meter as soon as it finishes.

Where is the data stored?

In your own MySQL database, on your network. Exact copies can be kept in SQL Server, SQLite or another MySQL server, and readings can be pushed to a SQL Server table for other systems. Nothing goes to a cloud unless you want it to.

Can it produce bills?

Yes. Tariffs with time-of-use periods and blocks are assigned per meter. Invoices are priced only from measured intervals, numbered without gaps, frozen when issued and corrected with credit notes. The monthly energy report and invoice drafts can be exported to Excel on a schedule.

Can other software use the data?

Yes, through a REST API with API keys and scopes (read, readings, meters, billing), CSV and Excel exports, the SQL Server push, or the database itself.

Where is MaxDLMS in service?

At the University of Jordan in Amman, reading 109 DLMS meters across the campus over TCP/IP into MySQL.